NEWS CENTER

Control cable application range

Source:
Release time:
2018/01/30
[Abstract]:
Scope of application The PVC insulated PVC sheathed control cable is suitable for wiring of control, signal, protection and measurement systems with rated voltages of 450/750V and below or 0.6/1kV and below.
Scope of application
        The PVC insulated PVC sheathed control cable is suitable for wiring of control, signal, protection and measurement systems with rated voltages of 450/750V and below or 0.6/1kV and below.
 
Use characteristics
 
● Power frequency rated voltage Uo / Uä o450 / 750V or 0.6 / 1kV.
 
● The cable conductor allows for a long-term maximum operating temperature of 70 °C.
 
● The ambient temperature should not be lower than 0 °C when the cable is laid. If the ambient temperature is lower than 0 °C, the cable should be preheated.
 
● The recommended bending radius of the cable is as follows:
 
Cables without armor shall not be less than 6 times the outer diameter of the cable;
 
Armored or copper tape shielded cable shall not be less than 12 times the outer diameter of the cable;
 
The shielded flexible cable should be no less than 6 times the outer diameter of the cable.
 
Model Product Name Voltage V Core Number Cross Section mm2 Main Scope
 
KVV copper-clad core PVC insulated and sheathed kvv cable 450/750 4-37 0.75-10 Laid indoors, cable trenches, pipes, etc.
 
KVV22 copper core PVC insulated and PVC sheathed steel tape armored kvv22 cable 450/750 4-37 0.75-10 It is laid indoors, cable trench, pipeline directly buried and other fixed occasions capable of withstanding large mechanical external force
 
KVVP flame-retardant copper core PVC insulated and sheathed kvvp cable 450/750 4-37 0.75-10 Laminated indoors, cable trenches, pipes, etc.
 
KVVR copper core PVC insulated PVC sheathed control flexible cable 450/750 4-37 0.75-10 Laid indoors, with moving requirements
 
KVVRP copper core PVC insulated and sheathed braided shielded control flexible cable 450/750 4-37 0.75-10 Laid indoors with moving shielding requirements
 
ZBKVV flame-retardant copper core PVC insulated and sheathed zrkvv cable 450/750 4-37 0.75-10 Laid indoors, cable trenches, pipes, etc.
 
ZBKVV22 copper core PVC insulated PVC sheathed braided steel tape armored zrkvv22 cable 450/750 4-37 0.75-10 Laid indoors, cable trenches, pipelines, etc. can withstand large mechanical external forces and have flame retardant requirements Fixed occasion
 
ZBKVVP copper core PVC insulated PVC sheathed braided shield zrkvvp cable 450/750 4-37 0.75-10 Laid indoors, cable trenches, pipes, etc.
 
ZBKVVR copper core PVC insulated PVC sheathed braided zrkvvr cable 450/750 4-37 0.75-10 Laid indoors with mobile and flame retardant requirements.
 
ZBKVVRP copper core PVC insulated PVC sheathed braided shield zrkvvrp cable 4